Frequency Minimum 80 MHz
Frequency Maximum 18 GHz (40 GHz)
Shield Room Inner Length: 13.41 m (44.00 ft)
Shield Room Inner Dim Width: 6.09 m (20.00 ft)
Shield Room Inner Dim Height: 4.87 m (16.00 ft)
Internal Working Volume Length: 4.50 m (14.76 ft)
Internal Working Volume Width: 4.00 m (13.12 ft)
Internal Working Volume Height 2.20 m (7.22 ft)
- Two ETS-Lindgen 6060 'Z' Fold Tuners, CW RF Shielded Bearing Mounting Assembly
- Two ETS-Lindgren Motor Base Drivers with Rotational Speed Control of 1 to 16 rpm
- Four LED Strip Light Fixtures (Electrical Distribution not Included)
- Installation of Enclosure and ETS-Lindgren Equipment
- Two 5.08 cm (2 in) Threaded Brass Pipe Penetrations with Flange Nuts and Caps
- Two Waveguide Vents, 30.48 cm x 30.48 cm (12 ft x 12 ft) in the Ceiling
- One Single-leaf, ETS-Ray Proof Series 201, Recessed Contact Mechanism (RCM), Manually Operated, RF-shielded Personnel Door, .91 m x 2.13 m (3 ft x 7 ft) Clear Opening
- One Connector Panel, 20.32 cm x 20.32 cm (8 in x 8 in)
- Reverberation Test per IEC 61000-4-21 in Steps from 80 MHz to 1 GHz per the Recommended Procedure
- Two Connector Panels, 15.24 cm x 61 cm (6 in x 24 in)
- Dielectric Floor Underlay 3.175 mm (.125 in) Thick
- Shield Test per IEEE 299, One Frequency Test at 1 GHz
- One Threaded Brass Ground Stud 1.27 cm (0.5 in) Diameter x 12.7 cm (5 in) Long
- Modular Shielded Room and Support Structure
- One ETS-Lindgren EMCenter™ with EMControl™ Device Controller Plug-in
- Interior Nominal Shield-to-shield Dimensions of 13.41 m x 6.09 m x 4.87 m (44 ft x 20 ft x 16 ft)
- One Door Maintenance Kit
- Guaranteed Performance and a Five-year Limited Warranty; One-year Warranty on Doors, Filters and Moving Parts; Two Year Warranty on Optional ETS-Lindgren's Equipment
- Sliding and/or Non-threshold Shielded Doors
- Seismic Structural Package
- One ULW 2 x 30 Amp, 60 Hz Power Line RF Filter
- Two 20 m Fiber Optic Cables
- Electrical Distribution
- Shielded Control Room
- Additional Filtering
- Large Equipment Access Doors
- Fire Detection and Suppression System
- Reverberation Performance Evaluation per SAE J1113/27
- Custom Room Sizes
- Two ETS-Lindgren Model 4860 Z-Fold Aluminum Paddles and Mounting Shafts, 1.21 m x 1.52 m x 6.70 m (48 in x 60 in x 22 ft)
- Field Uniformity Testing per MIL-STD 461E
- CCTV Monitoring System